06.03
13.9
Automatic controller setting
SIMODRIVE 611
universal
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
An automatic controller adjustment with HMI Advanced is not possible within the
framework of SINUMERIK 840Di.
For a description how to carry out an automatic controller adjustment of SIMO-
DRIVE 611 universal drives, please refer to:
References:
/FBU/ SIMODRIVE 611 Universal, Descriptions of Function
Section:Description of Functions
13 Drive Optimization using HMI Advanced
13.9 Automatic controller setting
Optimizing current and speed controllers
J
13-447