Miele G 600 Series Technical Information page 77

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

G 600/G 800
Note: Refer to the timing chart's legend for symbol descriptions.
C. Time column; indicates the length in time the step occurs. Minutes are on the left
side of the column, while seconds are displayed on the right side of the column.
"ZT #" refers to a thermal stop; see details below.
The minimum and
maximum amount
of time a thermal
stop can have.
The "ZT" in the time column
indicates a thermal stop and is
not a specified length of time.
Water inlet valves (Y2)
Whenever the Y2 valve is
activated, an "E" is present
in the column.
Example: The water inlet valves
are activated in Steps 3 and 6.
Technical Information
C
Water continues to circulate and is heated
at a rate of about 2 degrees Fahrenheit per
minute.
Heating and circulation continue until the
program temperature is reached.
Example: In the Universal program,
thermal stop (ZT2) needs to reach 56
degrees Celsius.
77

Advertisement

Table of Contents
loading

Table of Contents