Drain Pump, Circulation Pump; Figure 4-16: Condenser Drying System Components; Figure 4-17: Control Valve Y6 - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information

Figure 4-16: Condenser Drying System Components

If no voltage is applied to control valve Y6, the path between positions 1 and 3 in
Figure 4-17 is always open, so, during every water intake, the cold-water reservoir in
the steam condenser is filled with water from the water softener. If the reservoir is
full, excess water overflows at its top edge, then flows down and enters the cabinet
via the opening in the lower area of the side panel.
If voltage is applied to the control valve during water intake stages, the path between
positions 1 and 2 in Figure 4-17 is also open (this is marked with +K in the program
timing chart). Soft water will flow into the water mixer and then into the cabinet.

Figure 4-17: Control Valve Y6

4.19

Drain Pump, Circulation Pump

The drain pump (M8) is located below the cabinet and connects to the right/front of
the sump. The pump removes the wash water through the non-return valve and drain
hose to the on-site drain. The drain pump is controlled/powered by the electronic.
Note:
If the on-site drain is below the level of the guides for the bottom basket, the
drain must be vented to prevent siphoning. See the appropriate
operating/installation instructions or call Technical Support for assistance.
11 Softener
1 Soft water from water softener
2 Soft water to water mixer
3 Soft water to condenser module
40
G 600/G 800
1 Condenser control valve Y6
2 Fan M2
3 Vent/water port from condenser
4 Steam condenser assembly
5 Air duct (condenser intake)
6 Water intake assembly
7 Water hardness solenoid valve Y5
8 Cabinet vent/water port (un-softened)
9 Flow meter B3/4
10 Reactivation valve Y38