Ptc Release Element (Machines Equipped W/Turbothermic Fan); Combination Dispenser; Construction; Dispensing - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

G 600/G 800
4.2.1

PTC Release Element (Machines Equipped w/Turbothermic Fan)

When 120VAC is applied to the release element, the PTC resistor heats a small
grease-filled capsule. As the grease expands, it pushes a piston upward and slides
the air outlet flap to a partially open position. When the release element is activated
the second time, the piston slides the air outlet flap to a fully open position.
4.3

Combination Dispenser

4.3.1

Construction

Two individual solenoids control detergent and rinse aid dispensing.
The rinse aid reservoir has a capacity of about 130mL (4.4 fluid ounces). When the
rinse aid level drops to about 25mL (0.85 fluid ounces), the magnetic float activates a
reed switch on the edge of the dispenser and the rinse aid LED illuminates.

Figure 4-1: Dispenser Assembly

1 Rinse aid solenoid (120VAC), Y50
2 Detergent chamber flap solenoid (120VAC), Y51
3 Hose connection for condensate from fan (fan-equipped models only)
4 Rinse aid dispenser mechanism
5 Reed switch, B8/1
4.3.2

Dispensing

During the main wash, the detergent solenoid (Y51) is energized (120VAC) to open
the detergent dispenser flap. The water jet from the middle spray arm flushes
detergent out of the dispenser.
Model
C2.06
C2.09

Table 4-1: Detergent Quantity in Combination Dispensers C2.06 and C2.09

During the final rinse, the rinse aid solenoid (Y50) is energized (120VAC) to open the
Detergent Quantity
Pre-Wash Compartment (cm
25
20
Technical Information
3
)
Main Wash Compartment (cm
25
3
)
80
70