Resetting the Device to Factory Default

1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
The AMC2-4R4 now has the following network configuration:
The AMC2-4W now has the following network configuration:
Figure 5.7: Resetting the AMC2 to delivery state
Figure 5.8: Resetting the AMC2-DCUA to delivery state
2020-01 | V02 |
Reset the AMC2-4R4 as described above.
Open the upper case of the AMC2-4R4 as described in Opening the Case, page 36.
Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.
Press the reset button on the the board.
Set the DIL switches back in the address state before resetting.
Reset the AMC2-4W as described above.
Open the upper case of the AMC2-4W as described in Opening the Case, page 36.
Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.
Press the reset button on the the board.
Set the DIL switches back in the address state before resetting.
DHCP = 1
IP = [assigned by DHCP server or "0.0.0.0" if not available]
Subnet mask = [assigned by DHCP server or "0.0.0.0" if not available]
Password = no password
DHCP = 1
IP = [assigned by DHCP server or "0.0.0.0" if not available]
Subnet mask = [assigned by DHCP server or "0.0.0.0" if not available]
Password = no password
Installation manual
Access Modular Controller 2
Bosch Access Systems V.B.