Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
Table 6- 12
Table 6- 13
Table 6- 14
6SL3325-1TG31-0AAx
6SL3325-1TG31-5AAx
6SL3325-1TG32-2AAx
6SL3325-1TG33-3AAx
6SL3325-1TG35-8AAx
6SL3325-1TG38-1AAx
6SL3325-1TG41-0AAx
6SL3325-1TG41-3AAx
184
Max. pulse frequency when a dv/dt filter is used with Power Modules with a rated pulse
frequency of 2 kHz
Order number
6SL3315-1TE32-1AAx
6SL3315-1TE32-6AAx
6SL3315-1TE33-1AAx
6SL3315-1TE35-0AAx
Max. pulse frequency when a dv/dt filter is used with Motor Modules with a rated pulse
frequency of 2 kHz
Order number
6SL3325-1TE32-1AAx
6SL3325-1TE32-6AAx
6SL3325-1TE33-1AAx
6SL3325-1TE35-0AAx
Max. pulse frequency when a dv/dt filter is used with Motor Modules with a rated pulse
frequency of 1.25 kHz
Order number
6SL3325-1TE36-1AAx
6SL3325-1TE38-4AAx
6SL3325-1TE41-0AAx
6SL3325-1TE41-4AAx
Unit rating
Output current for a
[kW]
pulse frequency of 2 kHz [A]
Supply voltage 510 – 750 V DC
110
132
160
250
Unit rating
Output current for a
[kW]
pulse frequency of 2 kHz [A]
Supply voltage 510 – 750 V DC
110
132
160
250
Unit rating
Output current for a
[kW]
pulse frequency of 1.25 kHz
Supply voltage 510 – 750 V DC
315
450
560
800
Supply voltage 675 – 1080 V DC
90
132
200
315
560
800
1000
1200
Max. pulse frequency
when a dv/dt filter is used
210
260
310
490
Max. pulse frequency
when a dv/dt filter is used
210
260
310
490
Max. pulse frequency
when a dv/dt filter is used
[A]
605
840
985
1405
100
150
215
330
575
810
1025
1270
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz