Siemens SINAMICS S120 Equipment Manual page 172

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules
5.6 Technical specifications
Minimum cable lengths for parallel connection and connection to a motor with a single-winding
system
NOTICE
The minimum cable lengths specified in the tables below must be observed when two or
more Motor Modules are connected in parallel and there is a connection to a motor with a
single-winding system. If the cable length required for the application cannot be achieved, a
motor reactor must be provided.
Table 5- 19
6SL3325-1TE32-1AAx
6SL3325-1TE32-6AAx
6SL3325-1TE33-1AAx
6SL3325-1TE35-0AAx
6SL3325-1TE36-1AAx
6SL3325-1TE38-4AAx
6SL3325-1TE41-0AAx
6SL3325-1TE41-4AAx
Table 5- 20
6SL3325-1TG31-0AAx
6SL3325-1TG31-5AAx
6SL3325-1TG32-2AAx
6SL3325-1TG33-3AAx
6SL3325-1TG35-8AAx
6SL3325-1TG38-1AAx
6SL3325-1TG41-0AAx
6SL3325-1TG41-3AAx
170
510 to 750 V DC Motor Modules
Order number
675 to 1080 V DC Motor Modules
Order number
Unit rating
Output current
[kW]
110
132
160
250
315
450
560
800
1405
Unit rating
Output current
[kW]
90
132
200
315
560
800
1000
1025
1200
1270
Minimum cable length
[A]
210
260
310
490
605
840
985
Minimum cable length
[A]
100
150
215
330
575
810
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
[m]
30
27
20
15
13
9
8
5
[m]
90
70
50
30
20
15
10
8