Dc Link/Motor Connection - Siemens SINAMICS S120 Equipment Manual

Chassis liquid cooled power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

5.3.3

DC link/motor connection

Table 5- 2
DC link/motor connection of the Motor Module
Terminals
DCP, DCN
DC power input
U2, V2, W2
3 AC power output
PE connection
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
Technical specifications
Voltage:
510 to 750 V DC
675 to 1080 V DC
Connecting lugs: d = 13 mm (M12/50 Nm) for busbar connection
Voltage:
0 V 3 AC to 0.72 x DC link voltage
Connecting lugs:
Frame sizes FXL, GXL, HXL: D = 13 mm (M10/50 Nm) for cable lugs in accordance with
DIN 46234 / DIN 46235
Frame size JXL: D = 13 mm (M10/50 Nm) for busbar connection
Connecting lugs:
Frame sizes FXL, GXL, HXL: D = 13 mm (M10/50 Nm) for cable lugs in accordance with
DIN 46234 / DIN 46235
Frame size JXL: D = 13 mm (M10/50 Nm) for busbar connection
Motor Modules
5.3 Interface description
143

Advertisement

Table of Contents
loading