9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Value Range
En-bloc: The PBX sends all of the dialed digits at once after the extension user completes dialing. The PBX
recognizes the end of dialing when (1) # is dialed, if programmed, (2) a preprogrammed telephone number is
dialed, or (3) the inter-digit timer expires.
Overlap: The PBX sends dialed digits one at a time.
Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Programming Manual References
9.1 PBX Configuration—[1-1] Configuration—Slot
10.3 PBX Configuration—[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone—
Inter-digit
10.9 PBX Configuration—[2-9] System—System Options—Option 2—
Dial for en Bloc mode
11.1.4 PBX Configuration—[3-1-4] Group—Trunk Group—Dialing Plan
Feature Manual References
10.1.18 ISDN (INTEGRATED SERVICES DIGITAL NETWORK) FEATURES
Networking Data Transfer
Enables transmission of extension status data to connected PBXs in a network. This setting is only available
when
Port Type on this screen has been set to QSIG-Slave or QSIG-Master.
Default
Off
Value Range
Off, On
Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Programming Manual References
Section 17 PBX Configuration—[9] Private Network
Feature Manual References
15.1.14 Private Network Features—NDSS (Network Direct Station Selection)
Loopback Test started by Network
Enables a loopback test started from the network side, to be performed on the PRI23 card.