Ip-To-Remote Serial Application Example - GE MDS entraNET 900 Technical Manual

900 mhz and 2400 mhz extended range ip networking transceivers
Table of Contents

Advertisement

122
Table 5-1. IP-to-Local Serial Port Application Configuration
IP-to-local serial connection (Local Serial Gateway)
Radio Location
AP (COM2)
5.3 IP-to-Remote Serial Application
Example
This configuration makes any data sent or received with the AP with an
IP port number appear using the serial port of a single Remote (or of all
Remotes, if "Broadcast" is selected for Remote ID).
Figure 5-2. IP-to-Remote Serial Application Diagram
Table 5-2. IP-to-Remote Serial Application Configuration
MDS entraNET
Radio Location
AP (COM2)
Remote radio (COM2)
MDS entraNET Technical Manual
Menu Item
Port Status
Mode
RX IP Port
Baud Rate
Byte Format
Buffer Size
Invisible place holder
Menu Item
Setting
Remote ID
1155883
COM Port
COM2
Mode
TCP Server
Radio IP Port
30066
Mode
COM2 in transparent data mode
Baud
19200
Format
8N1
Buffer
256
DelayChars
4
Setting
Enabled
TCP
30011
19200
8N1
256 Bytes
05-4055A01, Rev. E