For Service Engineer
Service Information
(14) Make sure that the position of the head up/down (HL) axis overrun sensor and
mechanical stopper status are as follows.
(-)
Mechanical Stopper
-2 ± 0.75
1
Photo Sensor
(-)
Overrun
X0711
-1±0.1
(-)
(
Soft Limit)
-
(
0.5)
HL-Axis Zero
HL-Axis Full Stroke
25.0
(1.0)
((+) Soft Limit)
2
Unit : mm
(+) Mechanical Stopper
27 ± 0.35
Fig.D53
SI1705004E-00=SIGMA-G5SII Service Manual