Make sure there is enough space (greater than 10 cm (3.94 in)) around the air intake and outlet
vents on the firewall for good ventilation.
Make sure the installation site has a good cooling system.

ESD prevention

To prevent electrostatic discharge (ESD), note the following guidelines:
Make sure that the firewall and the floor are well grounded.
Take dust-proof measures for the equipment room.
Maintain the humidity and temperature at a proper level.
Always wear an ESD-preventive wrist strap when touching a circuit board or transceiver module.
Place the removed CF card or interface module on an antistatic workbench, with the face upward,
or put it into an antistatic bag.
Touch only the edges, instead of electronic components when observing or moving a removed CF
card or interface module.
To use the ESD-preventive wrist strap, perform the following steps:
Wear the wrist strap on your wrist.
Step1
Lock the wrist strap tight around your wrist to keep good contact with the skin.
Step2
Attach the ESD-preventive wrist strap to the rack with the alligator clips.
Step3
Make sure that the rack is well grounded.
Step4
Figure 4 Use an ESD-preventive wrist strap
(1) ESD-preventive wrist strap
(3) Alligator clip
CAUTION:
Check the resistance of the ESD-preventive wrist strap for safety. The resistance reading should be in the
range of 1 to 10 megohm (Mohm) between human body and the ground.
No ESD-preventive wrist strap is provided with the HP A-F1000-E firewall. Prepare it yourself.