Clean Axle Housing Air Breather - Hitachi ZW 310-6 Operator's Manual

Wheel loader
Hide thumbs Also See for ZW 310-6:
Table of Contents

Advertisement

Clean Axle Housing Air Breather

--- every 500 hours
Front Axle Breather (1)
Rear Axle Breather (2)
d
WARNING: When working under the raised lift
arm, be sure to avoid accidental injury or death by
placing a safety column or stand under the lift arm
to support it.
1. Clean the areas around the air breathers before
removing the air breathers.
Open the machine front cover. Front axle air breather
(1) is located at the right side.
Open the machine side cover. Rear axle air breather
(2) is located at the left side.
2. Put a cover on the air breather port to prevent foreign
matter from entering.
d
WARNING: Be sure to wear safety glasses when
cleaning the air breather with compressed air.
3. Clean the air breather using compressed air.
If completely contaminated, wash the air breather
with a cleaning solvent, blow it dry and reinstall it.
4. Take care not to allow foreign matter to enter into the
axle housing when reinstalling the air breather.
MAINTENANCE
1
2
7-41
90Z7-7-36-1
90Z7B-7-43-3

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents