Adapter Cable 1 684 465 843 (Crin) - Bosch 1 687 010 398 Original Instructions Manual

Extension set for bosch commercial vehicle injectors with injector clamping and injection chamber
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
3.6.3
Hose 1680 712 360
!
Always ensure cleanliness when setting down the
hose, e.g. on a workbench surface. Before connect-
ing the hoses to the unit under test always make
sure the hose connections are clean.
The hose 1 680 712 360 connects the CRIN test oil re-
turn to the return quantity test connection.
1 687 712 360
Fig. 11:
Hose 1 680 712 360
3.6.4

Adapter cable 1 684 465 843 (CRIN)

The adapter cable is required for actuation of the CRIN
via the 1 687 010 398.
1 684 465 843
Fig. 12:
Adapter cable 1 684 465 843
Robert Bosch GmbH
Product description | 1 687 010 398 | 25
3.6.5
The return adapter accessory set is needed for CRIN
with split return quantity.
4
458881-19_Ko
Fig. 13:
1. Screw the plug-in nipple (Fig. 13, Item 1) with flat
sealing ring (10.2 x 13.4 mm) into the distributor
head (Fig. 13, Item 2) and secure.
458881-40_Ko
2. Screw the hose connection (Fig. 13, Item 3) with flat
sealing ring (10.2 x 13.4 mm) into the end face of
the distributor head and secure.
3. Attach both hoses (Fig. 13, Item 4) to the hose con-
nections and secure with two hose clamps (Fig. 13,
Item 5).
4. Fit the other two hose clamps on the other end of
the hoses.
Connection of return adapter for CRIN with split
return quantity
Fig. 14:
Return adapter accessory set 1 687 016 038
1
3
2
5
5
Fitting return adapter
Connection of return adapter