External program memory
External program memory can be found on the following data carriers:
● Local drive
● Network drive
● USB drive
Note
Only the USB interfaces on the operator panel front or the TCU can be used as interface
for the processing of an external program on a USB drive.
Applications
● Direct execution from external programs
In principle, any program that is accessible via the directory structure of the interface in the
"Execution from external" HMI mode can be selected and executed.
● Execution of external subprograms from the part program
The external subprogram is called through the part program command EXTCALL with
specification of a call path (optional) and the subprogram name (→ see "Executing external
subprograms (EXTCALL) (Page 600)").
Parameter assignment
A reloading memory (FIFO buffer) must be reserved in the dynamic NC memory for executing
a program in "execution from external source" mode.
Size of FIFO buffer
The size of the FIFO buffer is set in the machine data:
MD18360 $MN_MM_EXT_PROG_BUFFER_SIZE (FIFO buffer size for processing from
external)
Note
Programs with jump commands
For external programs that contain jump commands (GOTOF, GOTOB, CASE, FOR, LOOP,
WHILE, REPEAT, IF, ELSE, ENDIF etc.) the jump destinations must lie within the post loading
memory.
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
NOTICE
Tool/workpiece damage caused by the USB FlashDrive
It is recommended that a USB-FlashDrive is not used for the execution of an external
subprogram. A communication interruption to the USB FlashDrive during the execution of
the subprogram due to contact problems, failure, abort through trigger or unintentional
unplugging, results in an immediate machining stop. The tool and/or workpiece could be
damaged.