Smart Matching Template Setting
Set a template of Smart Matching.
A template that can be set with the command is one of Smart Matching in "Checker" menu. In Smart Matching
used in Position Adjustment and Area Size Adjustment, a template cannot be re-registered.
For information on the conditions when re-registering templates: page 127 w
When "Area Display" is set to "No" for Template Setting
% A n
Send
Receive
% A $
Error (ERROR 0 signal = ON)
% A
Error code
200
230
231
232
233
Example:
Re-registers a template No.1 of checker No.5.
Send
Receive
408
n
n
,
?
?
BCC
BCC(40)
CR
!
Error code (3-digit)
Operation is stopped
•
Although PV500 is operating (RUN), displaying SETUP menu cannot
switch layout.
•
Because PV500 is processing Detect trigger or Continuous Inspection,
Template setting cannot be executed.
•
The command (%A) when "Area Display" is set to "Yes" was sent.
•
The specified checker number or template number has not be created.
•
Other number than 000-999 for checker number, or 00-63 for template
was specified.
Template cannot be set because no image has been captured after PV500
started up when you select "Use the Last Image" for "Template Setting".
•
No feature on the image of template registration area.
•
An error occurs in Position adjustment when you use it.
•
Template registration area is outside of the captured image (image
partially captured when executing partial imaging). (The whole template
setting area should be in the range of the captured image.)
% A 0
0
5
,
% A $
4
0 CR
CR
nnn = 000 - 999 (Checker No.)
?? = 00 – 63 (Template No.)
BCC
CR
0
1
*
*
CR