Panasonic PV500 User Manual page 109

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

Setting an Inspection Area
Set a range to detect an object.
You cannot set a Mask Area in Binary Edge checker.
1.
Select "Area Setting" in "Binary Edge" setting window.
2.
Select "Area (Set)".
"Area Setting" window is displayed.
3.
Select a shape of inspection area from "Change Shape".
Select from Line and Plane.
For detecting a flat edge at high speed, Line scan is suitable. And Plane scan
suits for detecting a round or pointed edge.
4.
Select "Change" and draw an area.
Refer to section of Drawing an Inspection Area (page 47).
5.
After drawing is completed, press the CANCEL key.
Using Area Size Adjustment
Area Size Adjustment is a function for inspecting variable-sized objects. The function adjusts an inspection
area according to the size of the object detected with Area Size Adjustment checker. Refer to Chapter 4.9,
page 208 about Area Size Adjustment and the setting procedure.
Selecting Detect Condition of Edge
Set detailed conditions such as detecting direction of edge.
1.
Select "Inspection Condition".
Set Scan Direction, Edge Condition, Detected Position.
2.
Select "Search Method".
Set "Filter" and "Width".
About Conditions
Scan direction (Horizontal/Vertical) -- Only Plane scan
Horizontal:
Scans horizontally* from the start to the end points.
Vertical:
Scans vertically* from the start to the end points.
*If you set a rotated area, it scans at the rotated angle.
Scan direction = Horizontal
107