When Execution Mode is "Automatic Switch" or
"User-Defined"
1.
Select "Condition" in judgement output
setting window.
"Condition" setting window is displayed.
2.
Select "Save Image Memory" in the item
selecting field on the upper left.
The list of the Save Image Memory by
blocks is displayed.
3.
Select "Condition" column of the block No. to set in the list and select a judgment type.
For details, refer to the procedure of "Execute All" execution mode.
4.
Select "Checker No." column and set a judgment number.
5.
After setting is completed, press the CANCEL key.
Now you completed registering.
In case of automatic switch, as for the image memory save, only the setting for the block finally executed is
enabled.
For example, if executing the operation in the order of block No. 0 -> block No.1 when the conditions for the
image memory save have been set for the block No. 0 only, the image memory save is not executed as the
conditions for the image memory save have not been set for the block No. 1 finally executed.