Siemens Sinamics S120 Function Manual page 567

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Bit
Meaning
7
Digital input/output 15
(DI/DO 15)
8 ... 15
Reserved
Note:
The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also transmit signal
E_DIGITAL).
MT_STW
Control word for the "central probe" function. Display via r0685.
Table 10- 43 Description of MT_STW (control word for Control Unit)
Bit
0
Falling edge probe 1
1
Falling edge probe 2
2
Falling edge probe 3
3
Falling edge probe 4
4
Falling edge probe 5
5
Falling edge probe 6
6
Falling edge probe 7
7
Falling edge probe 8
8
Rising edge probe 1
9
Rising edge probe 2
10
Rising edge probe 3
11
Rising edge probe 4
12
Rising edge probe 5
13
Rising edge probe 6
14
Rising edge probe 7
15
Rising edge probe 8
CU_ZSW1 (status word of the DO1 telegram (telegrams 39x))
See function diagram [2496].
Table 10- 44 Description of CU_ZSW1 (status word of the CU)
Bit
Meaning
0
Reserved
1
Reserved
2
Reserved
3
Fault active
No fault present
4
Reserved
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
DI/DO 15 on the Control Unit must be parameterized as an output
(p0728.15 = 1).
Meaning
-
-
-
1
0
-
10.1 Communication according to PROFIdrive
Remarks
Remarks
Activation of measuring time determination with the
next falling edge
For telegram 392, in addition, probes 3 and 6
For telegram 393, in addition, probes 7 and 8
Activation of measuring time determination with the
next rising edge
For telegram 392, in addition, probes 3 and 6
For telegram 393, in addition, probes 7 and 8
Remarks
-
-
-
The active faults are stored in the fault buffer
There are no faults in the fault buffer
Communication
Parameter
BI: p0745
Parameter
CI: p0682
Parameter
-
-
-
BO: r2139.3
-
565