When an encoder is parked, the encoder being addressed is switched to inactive (r0146 =
0).
● Control is carried out via the encoder control/status words of the cyclic telegram
● With a parked motor measuring system, the associated drive must be brought to a
● The monitoring functions for the power unit remain active (r0126 = 1).
Example: parking axis
In the following example, an axis is parked. To ensure that the axis parking is effective, the
drive must be brought to a standstill (e.g. via STW1.0 (OFF1). All components assigned to
the motor control (e.g. power unit and motor encoder) are shut down.
Figure 6-11
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
(Gn_STW.14 and Gn_ZSW.14).
standstill by the higher-level control system (disable pulses e.g. via CTW1.0/OFF1).
Note
Removing/replacing parked components
Once parked components have been disconnected/connected, they can only be
unparked once they have been successfully integrated in the actual topology. (See
r7853)
Function chart: parking axis
6.19 Parking axis and parking encoder
Basic functions
291