DRX-2
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
74
DS_SYS_VirginModeOff
1221
Turn off the virgin mode functionality (e.g. the auto channel search upon start-up)
-
Issue the command to reset the bit for the virgin mode to the analog board
-
Wait for the result and return this to the user
Less than 1 second.
None
Number
Description
122100
Turning off the virgin mode succeeded
122101
Turning off VirginMode on the Analog Board failed.
122102
The returned errorcode from the analog board is unknown:
122103
No DS errCode known for analog board error:
122104
There was no response from the analog board.
DS:> 1221
122100:
Test OK @
DS_SYS_DisplayFatalOn
1223
Turn on the display-fatal functionality which displays debug-information on the display when
encountering a fatal error condition from which could not be recovered automatically
-
Issue the command to use the display-fatal functionality to the analog board
-
Wait for the result and return this to the user
Less than 1 second.
None
Number
Description
122300
Turning on the display-fatal functionality succeeded
122301
Turning on the display-fatal functionality failed
122302
The returned errorcode from the analog board is unknown:
122303
No DS errCode known for analog board error:
122304
There was no response from the analog board.
DS:> 1223
122300:
Test OK @
DS_SYS_DisplayFatalOff
1224
Turn off the display-fatal functionality which displays debug-information on the display when
encountering a fatal error condition from which could not be recovered automatically
Issue the command to stop using the display-fatal functionality to the analog board
Wait for the result and return this to the user
Less than 1 second.
None
Number
Description
122400
Turning off the display-fatal functionality succeeded
122401
Turning off the display-fatal functionality failed
122402
The returned errorcode from the analog board is unknown:
122403
No DS errCode known for analog board error:
122404
There was no response from the analog board.
DS:> 1224
122400:
Test OK @