Philips SOPHO 2000 IPS User Manual page 334

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

LED INDICATION
LED
NORMAL
RUN
Flash
(120 IPM)
LC
On
PCM
Off
FRM
Off
MFRM
Off
RMT
Off
Alarm Indications on 30PRT
FAULT
CAUSE
On or Off
Abnormal opera-
tion of PRT card
Off
ISDN Primary Rate
D-channel data link
connection failure
On
No PCM signals
arrive from the dis-
tant office
On
Frame Alignment
signals from the
distant office can-
not be received
On
Multi Frame Align-
ment signals from
the distant office
cannot be received
On
Frame Alignment
signals cannot be
sent to the remote
PBX
– 320 –
CHAPTER 5 OPERATION TEST
INTEROFFICE TRANSMISSION LINE TEST
FAULT
ACTION
1
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
2
Check to see if the SENSE switch
is set as per the AP number (04-
15, 20-31) assigned by CM05
Y=0.
3
Reset the MB switch
(Down→Up→Down)
If the fault cannot be cleared,
4
replace the card.
Check the status of the local office line
or public network line.
1
Check to see if the line is correctly
connected to the PRT card.
2
Plug and unplug the PRT card.
Repeat this two or three times.
1
Check the receive line and exter-
nal equipment.
2
Replace the remote PRT card.
1
Check the receive line and exter-
nal equipment.
2
Replace the remote PRT card.
1
Check the transmission line and
external equipment.
2
Replace the PRT card.
Continued on next page
NWA-008852-001 Rev.5.0
98ch5001.fm

Advertisement

Table of Contents
loading

Table of Contents