SWITCH NAME
SW0
(Piano Key SW)
OFF
8
7
6
5
4
3
2
1
ON
SWITCH
SETTING
NUMBER
POSITION
ON
1
NOTE 3
NOTE 4
OFF
ON
2
NOTE 3
NOTE 4
OFF
ON
3
NOTE 6
OFF
ON
4
NOTE 6
OFF
ON
5
NOTE 6
OFF
ON
6
NOTE 6
OFF
ON
7
NOTE 6
OFF
8
OFF
FUNCTION
Source clock signal from network is
sent to the PLO0 input on MP card.
Source clock signal from network is not
sent to the PLO0 input on MP card.
Source clock signal from network is
sent to the PLO1 input on MP card.
Source clock signal from network is not
sent to the PLO1 input on MP card.
Remote loopback
For normal operation
Local loopback (AIS send)
For normal operation
Set equalizer according to the cable
length between the PBX and the C.O.
or CSU.
• For DS-1 (SW1-3 ON)
SW0-5 SW0-6 SW0-7
ON
ON
ON
1199-1758 m (3930-5764 ft.)
OFF ON
ON
599-1199 m (1965-3930 ft.)
ON
OFF ON
0-599 m (0-1965 ft.)
OFF OFF ON
Not used
OFF OFF OFF Signal is not sent
• For DSX-1/Hong Kong/Taiwan
(SW1-3 OFF)
SW0-5 SW0-6 SW0-7 CABLE LENGTH TO CSU (0.65 φ)
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF ON
ON
OFF OFF
OFF
Not used
– 244 –
PN-24DTA-C (DTI)
CABLE LENGTH TO CSU (0.5 φ)
0-40 m (0-131.2 ft.)
40-80 m (131.2-262.5 ft.)
80-120 m (262.5-394 ft.)
120-160 m (394-525 ft.)
160-200 m (525-656 ft.)
Signal is not sent