Philips SOPHO 2000 IPS User Manual page 32

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

The way of Terminal Endpoint Identifier (TEI) assignment for the combination of the terminal connection
form and each BRT card shows the table below.
BRT
Connection Form
BRT Card
PN-BRTA/
Point-to-Point Connection
PN-2BRTC/
Point-to-Multipoint Con-
PN-2BRTK
nection
Service Profile ID (SPID)
for Voice Channel
[North America Only]
PN-4BRTA-A Point-to-Point Connection
Point-to-Multipoint Con-
nection
Service Profile ID (SPID)
for Voice Channel
[North America Only]
*1 TEI value is assigned for each B channel. Therefore, two TEI values are used.
*2 Automatic TEI Assignment (TEI=64-126) is available for Series 3800 software or later. When us-
ing Series 3700 software or before, use Non-Automatic TEI Assignment (TEI=0).
*3 Non-Automatic TEI Assignment and Automatic TEI Assignment can be assigned for each D chan-
nel.
[Series 3800 software or later]
*4 Assign Non-Automatic TEI Assignment when connecting to the regular ISDN network. According
to the specification of the ISDN network, assign Automatic TEI Assignment only when Automatic
TEI Assignment is required.
Terminal
for ISDN-BRI
CHAPTER 1 GENERAL INFORMATION
Non-Automatic TEI Assignment
0
1
×
×
×
×
×
– 18 –
SYSTEM OUTLINE
×: Available –: Not available
TEI Value
Automatic TEI
Assignment
2-63
64-126
*2, *3, *4
NWA-008852-001 Rev.5.0
×
×
*1
×
98ch1001.fm
JULY/13/2007

Advertisement

Table of Contents
loading

Table of Contents