Toshiba Strata DK 280 Installation Manual page 555

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Program 77-1
-
Peripheral
Options
(Door
Phones)
RSIU/RSIS/RMDS/IMDU/PIOU/PIOUS/PEPU
SELECT = 1 I-
.
LED/Button
Light the Buttons/LEDs that are marked
with an X in the table below.
l--E-L-
LED ON
I
LED OFF
I
I
I
20
Door Lock Time/6 sec.
1 Door Lock Time/3 sec.
I
I
191m5 1
Port 02WDDCB 4 or1 HDCB 4
1 Port 028ITelephone
I
I
I
181s5
1
Port 020/DDCB 3 or1 HDCB 3
1 Port 020/Telephone
I i
I
171s5
1
Port 012/DDCB 2 ori HDCB 2
1 Port 012/Telephone
I
161V5 1
Port 004/DDCB 1 or1 HDCB 1
1 Port 004/Telephone,
RMDS Modem Protocol CCllT (2400 bps)8
1 RMDS Modem Protocol Bell21 2A (1200 bps)a I
CR311
15
1
I
I
14
RMDS/IMDU'
Modem (DN #I S)/Enabled'
I RMDS/IMDU7 Modem (DN #lS)/Disabled
I
I log I
Enable 280ADMIN/BACKUP
Protocol
I
Disable 280ADMIN/BACKUP
Protocol
-7
I
I
08
Door Phone Ring on Ext Page3
Door Lock Relay Enabled4
No Ring over Ext Page
1
I
External Page Relay Enabled4
-1
I
I
07
06
I I
NT
Relay with NT1 or NT2 Button and
ringing CO line6
NT Relay Steady with NT1 Button
I
I
05
MOH Relay Enabled
NT Relay Enabled
I
04
I
Notes:
DKOS89
1.
DDCEYHDCB = Door Phone/Lock
Control Unit. Up to four DDCBs/HDCBs
can be installed in a system with RCTV B,
RCTVBA/BB
and C/D, only 3 are allowed with RCTV A. They must be assigned a PDKU, RDSV, PEKU or PESV port number
to
operate
(DDCB to PDKV or RDSV, and HDCB to PEKV or PESV). (See Program 79 and
*79 for door phone ringing
assignments).
2.
If a modem unit (RMDSIMDV)
is installed, it can be accessed by dialing Station #I9 and can be assigned a DID extension
number in Program
%I9 or in Program 71 (1 - 3).
3.
The door phone will ring over external page if the DK system is in the NiGHT mode.
4.
This option applies to the PIOV/PIOVS/PEPV
Door Lock Control 0 assigned to electronic or digital telephone buttons using
Code 471 in Program 39; it does not apply to DDCB or HDCB Door Lock Control.
5.
Station PCBs that are connected to HDCBIDDCB
door phones control boxes must be installed in lower slot numbers than tie,
DID, or Attendant Console PCBs.
6.
CO lines must be assigned to night ring over External Page (Program
78-l) to allow the NT relay to operate when incoming CO
tines ring.
7.
See Program 79 and *Program
*79 for door phone ringing assignments.
8.
IMDV can be 1200 bps or 300 bps as set by SW2 on the PIOV or PIOUS PCB; RMDS can be 1200 bps or 2400 bps as set in
Program 76-2 and Program 77- 1 LED 15.
9.
The Toshiba 28OAdmin/Backup
software programs
will automatically
turn ON LED IO when the programs communicate
with the
DK280 locally or remotely.
General Notes:
l
For more information,
see the instructions preceding
the record sheets.
.
Initialized data leaves all LEDs OFF.
,
-
-
-
-
January 1996
1 o-1 41