Chapter 13: Troubleshooting the Emulation Module
Emulation Module Built-in Commands
only one emulation module installed, the command might look like this:
telnet test2 6472
4 If you do not see a prompt, press the
To exit from this telnet session, type
To use the built-in commands
Here are a few commonly used built-in commands:
Useful built-in commands
b
Break—go into the background monitor state
cf
Configuration—read or write configuration options
help
Help—display online help for built-in commands
init
Initialize—init -c re-initializes everything in the emulation module
except for the LAN software; init -p is the equivalent of cycling
power (it will break LAN connections)
lan
configure LAN address (emulation probes only)
m
Memory—read or write memory
pp load
Load EMSIM values into preprocessor
reg
Register—read or write a register
r
Run—start running user code
rep
Repeat—repeat a command or group of commands
rst
Reset—reset the target processor (the emulation module will wait
for you to press the target's RESET button)
s
Step—do a low-level single step
sync diff
Compare EMSIM with SIM registers
sync emsim
Copy EMSIM to SIM registers
sync sim
Copy SIM to EMSIM registers
ver
Version—display the product number and firmware version of the
emulation module