Chapter 8: Using the Emulator with a Debugger
Using the Software Development Systems debugger
Error conditions
"!ERROR 800! Invalid command: bcast" usually means that there is not
a target interface module (TIM) connected to the emulation module or
the emulation module does not have firmware for the CPU32 family.
Verify that the emulation module is connected to the target. Next, go
to the system window of the logic analyzer interface and verify that the
Emulation Module icon (stop-light) is described as a Motorola CPU16/
32 BDM Emulator. If it is not, follow the steps on page 144 to update
the firmware in the emulation module.
"command socket connection failed: WSAECONNREFUSED:
connection refused" usually means the emulation module is not at port
#6470 on the Logic Analysis System. See step 2 of the getting started
section above.
"unrecognized hostname"
usually means that the debugger is unable to establish communication
with the emulator. Verify communication to the emulation module by
doing a ping to the logic analyzer. If you are unable to ping the logic
analyzer refer to page 275 for more information.
The SDS web site: http://www.sdsi.com
See Also
The SDS SingleStep Users Guide.
The configuration section beginning on page 146 for more information
on configuration options and the "cf" command.