Connecting Power and Turning the Power On

A power switch and a receptacle for the power cord are located on each power supply on the
back of the appliance as shown in

Figure 9 Power Switch Location

Caution
To avoid potential service interruptions from momentary facility power interruptions and
potential power spikes that might damage your equipment, Check Point strongly
recommends that you use an uninterruptible power supply (UPS) with surge protection
with your IP2450 appliance.
To connect the power supply
1. Connect the power cord securely into the power cord receptacle on the power supply.
2. Plug the other end of the power cord into a three wire grounded power strip or wall outlet.
3. Toggle the 1/O power switch to the 1 position to provide power to the IP2450 appliance.
The fan unit on the power supply turns on when you press the power switch. Verify that the
power supply fans are running after you press the switch.
Note
The IP2450 appliance power supply automatically detects the input voltage (115 VAC or
220 VAC [85 to 264]) and configures itself appropriately.
If the fans are not running, make sure:
The power cord is properly connected.
Check Point IP2450 Security Platform Installation Guide
Figure
Power supplies
700W AC
700W AC
Power cord receptacles
Connecting Power and Turning the Power On
9.
FAULT
OVER
TEMP
PWR OK
FAULT
OVER
TEMP
PWR OK
Power switch
00623
39