DCBX Feature Information
DCBX Port Feature Statemachine Info
==================================================================================
Alias Port Type AdmState Will Advrt OpVer MxVer PrWill SeqNo Err OperMode Syncd
1 1 ETS enabled No Yes 0 0 No 1 No disabled No
1 1 PFC enabled No Yes 0 0 No 1 No disabled No
1 1 AppProt disabled No Yes 0 0 No 1 No disabled No
2 2 ETS enabled No Yes 0 0 No 1 No disabled No
2 2 PFC enabled No Yes 0 0 No 1 No disabled No
2 2 AppProt disabled No Yes 0 0 No 1 No disabled No
3 3 ETS enabled No Yes 0 0 No 1 No disabled No
3 3 PFC enabled No Yes 0 0 No 1 No disabled No
3 3 AppProt disabled No Yes 0 0 No 1 No disabled No
4 4 ETS enabled No Yes 0 0 No 1 No disabled No
4 4 PFC enabled No Yes 0 0 No 1 No disabled No
4 4 AppProt disabled No Yes 0 0 No 1 No disabled No
5 5 ETS enabled No Yes 0 0 No 1 No disabled No
5 5 PFC enabled No Yes 0 0 No 1 No disabled No
5 5 AppProt disabled No Yes 0 0 No 1 No disabled No
...
© Copyright Lenovo 2017
The following command displays DCBX Feature information:
show cee information dcbx port <port alias or number> feature
Command mode: All
The following table describes the DCBX Feature information.
Table 80.
DCBX Feature Information Fields
Parameter
Description
Alias
Displays each port's alias.
Port
Displays each port's number.
Type
Feature type
AdmState
Feature status (Enabled or Disabled)
Will
Willing flag status (Yes/True or No/Untrue)
Advrt
Advertisement flag status (Yes/True or No/Untrue)
OpVer
Operating version negotiated with the peer device
MxVer
Maximum operating version supported by the system
PrWill
Peer's Willing flag status (Yes/True or No/Untrue)
SeqNo
Sequence number that changes each time a DCBX parameter in
one or more DCB feature TLVs changes
Err
Error condition flag (Yes or No). Yes indicates that an error
occurred during the exchange of configuration data with the
peer.
Chapter 2: Information Commands