ABB ACS5000 User Manual page 99

Water-cooled
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

A
3
Figure 6-6 Wiring across shipping splits, frame size 1 (A) and 2 (B)
(1) Shipping split PCUx1 – PCUx1
(2) Cable ducts on each side of
the shipping split for:
- Auxiliary power supply cables
- Optical fibers
- Signal cables
(3) Connection point for
charging cable
3BHS799208 E01 REV E
5
ACS5000 WATER-COOLED USER MANUAL
06 ELECTRICAL INSTALLATION
B
1
5
(4) Charging cable behind water pipe
(not illustrated), laid on the
brackets and connected to
the busbar
(5) PCUx1
2
2
4
99/186