Preparing Cables For Cable Entries With Sealing Modules - ABB ACS5000 User Manual

Water-cooled
Hide thumbs Also See for ACS5000:
Table of Contents

Advertisement

6.8.1.1

Preparing cables for cable entries with sealing modules

1. Unscrew the frame and remove the sealing modules.
Note: For information on removing and installing the sealing modules
and using the compression wedge, see "Appendix A –
Additional manuals".
2. Prepare the cables with an outer cable screen for EMC bonding with
the metal enclosure of the cabinet as illustrated.
(1) Sealing module
(2) Conductive foil
(3) Cable sheath removed to expose
cable shield
3BHS799208 E01 REV E
Figure 6-19 Preparing control cables for sealing modules
ACS5000 WATER-COOLED USER MANUAL
06 ELECTRICAL INSTALLATION
1
2
3
4
4
4
(4) Conductor screen extension to be
connected to PE terminal
114/186