HP 37718A Installation And Verification Manual page 136

Communications performance analyzer
Hide thumbs Also See for 37718A:
Table of Contents

Advertisement

Performance Tests
SDH/SONET Receiver Monitor Levels
SDH/SONET Receiver Monitor Levels
Specifications
Bit Rate
STM-0/STS-1 - 51.84 Mb/s
STM-1/STS-3 - 155.52 Mb/s
Description
The signal from the HP37718A/19A SDH/SONET Transmitter is applied
to the SDH/SONET Receiver after attenuating by an amount equal to
the selected Receiver Flat Loss plus the specified Cable Loss. The Flat
Loss is obtained from a 75Ω, attenuator kit. The Cable Loss is supplied
by inserting the correct Cable Simulators for each bit rate in the
attenuation path.
Equipment Required
Cable Simulator STM-0/STS-1 50 metres of 8120-0049
Cable Simulator STM-1/STS-3 75 metres of 8120-0049
75Ω Attenuator Kit
Procedure
1 Recall the HP37718A/19A DEFAULT SETTINGS as shown on Page 3-
2.
2 Connect the equipment as shown in Figure 3-5.
3-68
Nominal
Equalization at 1/2
Loss
20, 26dB
20, 26dB
HP 86213A
Bit Rate
12dB
12dB

Advertisement

Table of Contents
loading

This manual is also suitable for:

37719a

Table of Contents