Commissioning
4.4 Creating a project offline in Startdrive
4.4.9.1
Adding a CBE20 Communication Board
Preconditions
● A project has been created.
● A Control Unit is contained in the device configuration.
● No Terminal Board TB30 is contained in the device configuration.
TB30 and CBE20 cannot be created simultaneously in the device configuration.
Procedure
The CBE20 is a versatile Communication Board that can be used in Startdrive with the
"SINAMICS-Link" communication profile.
1. Open "Supplementary system components > Communication Boards" in the hardware
catalog.
2. Select the "CBE20 Communication Board" in the device overview.
3. Drag the "Communication Board CBE20" into the device view into the light gray border
area of the Control Unit.
Result
The CBE20 is inserted in the drive, and does not have to be specified in any more detail.
4.4.9.2
Adding a Terminal Board
Terminal Board TB30 is a terminal module with which it is possible to expand the interfaces
of the Control Unit. The Terminal Board is inserted into the option slot of the Control Unit.
The Terminal Board does not have to be specified any further.
Preconditions
● A project has been created.
● A Control Unit is contained in the device configuration.
● No Communication Board CBE20 is contained in the device configuration.
TB30 and CBE20 cannot be created simultaneously in the device configuration.
Procedure
1. Open "Additional system components > Terminal Boards" in the hardware catalog.
The "TB30 Terminal Board" entry is displayed.
2. Select the TB30 Terminal Board in the device overview.
3. Drag the Terminal Board to the device view.
124
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0