Siemens SINAMICS S120 Manual page 40

Cabinet modules
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

System overview
2.10 System data
Ambient conditions
Ambient temperature
Relative humidity
(condensation not permissible)
corresponds to class
Installation altitude
Deviations from the specified class are shown in
2)
Mechanical strength
Vibrational load
- Displacement
- Acceleration
- Corresponds to class
Shock load
- Acceleration
- Corresponds to class
Deviations from the specified class are shown in
3)
Note
Weight of a cabinet unit
The relevant weight of a cabinet unit is specified on the test certificate supplied and on the
rating plate. The specified weight corresponds to the actual expansion stage of the cabinet
unit.
Note
Limiting overvoltages
On systems with a grounded phase conductor and a line voltage > 600 V AC, line-side
components should be installed to limit overvoltages to overvoltage category II in
accordance with EN 61800-5-1.
38
Operation
0 °C
... +40 °C
2)
to +50 °C see derating data
95 %
5 % ...
2)
3K3 acc. to EN 60721-3-3
Motor Modules, Booksize Cabinet Kit format:
up to 1000 m above sea level - no derating,
> 1000 m - see characteristics/derating data
Cabinet Modules:
up to 2000 m above sea level - no derating,
> 2000 m - see characteristics/derating data
italics
.
Operation
0.075 mm at 10 ... 58 Hz
9.8 m/s² at >58 ... 200 Hz
-
100 m/s
for 11 ms
2
3M4 to EN 60721-3-3
italics
.
Storage
-25 °C to +55 °C
5 %
... 95 %
2)
2)
1K4 acc. to EN 60721-3-1
Storage
5 Hz
1.5 mm at
... 9 Hz
3)
5 m/s² at >9 ... 200 Hz
1M2 acc. to EN 60721-3-1
40 m/s
for 22 ms
2
1M2 to EN 60721-3-1
Transport
-25 °C to +70 °C
-40 °C
from
for 24 hours
2)
5 % ... 95% at 40 °C
2K3 to EN 60 721-3-2
Transport
5 Hz
3.1 mm at
... 9 Hz
3)
10 m/s² at >9 ... 200 Hz
2M2 acc. to EN 60721-3-2
100 m/s
for 11 ms
2
2M2 to EN 60721-3-2
Cabinet Modules
Manual, 03/2013, A5E03263538A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents