4.2.4
Measuring corner
4.2.4.1
General information
Prerequisite
The workpiece probe is the active tool with activated tool offsets in the spindle and is already
calibrated (refer to "Calibrating workpiece probe" chapter).
Selection display
After selecting "corner", a selection display is shown containing the following options:
• "right-angled corner"
• "any corner"
Note
Set the feedrate override to the same value as for calibration!
Measuring cycles
Programming Manual, Release 04/2006, 6FC5398-4BP10-0BA0
Measuring in JOG
4.2 Workpiece measurement
4-19