Standby [On/Off]; Stat - GE MDS 4790 Series Installation & Operation Manual

400 mhz/900 mhz multiple address system master station radio
Table of Contents

Advertisement

Standby Hardware
Configuration
Alarm Status
Display
56
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx

STANDBY [ON/OFF]

Use the
command to notify the monitoring processor of the
STANDBY
presence of a second radio assembly within the chassis so that it can
switch to the alternate radio if the primary radio assembly fails.
= Chassis is equipped with two radio assemblies
STANDBY ON
= Chassis equipped with only one radio assembly
STANDBY OFF
Responses to the STANBY command are:
STANDBY DEFINED
STANDBY NOT DEFINED

STAT

The
command provides a user-friendly, interactive way to view
STAT
alarm status (the
ALARM
hexadecimal format).
If no alarm event conditions are active, the message
is shown. If alarms are present, they are shown in ascending
PRESENT
order starting with the lowest event number:
E v e n t : 2 6 ( M I N O R )
D C i n p u t p o w e r i s n ot i n v a l i d
r a n g e
Major alarms are displayed first, followed by minor alarms.
The command output shows the event number, major/minor status, and
a one- or two-line text message. If additional alarm events are active, the
prompt is shown.
MORE>
• Press the Enter key to display the next alarm event
• Enter
,
, or a period (.) to return to the command prompt
QUIT
Q
MDS 4790/9790 Series I/O Guide
Standby Equipment
A
B
Page 73
= The chassis is equipped with two
radio assemblies
= The chassis is equipped with only
one radio assembly
Active Radio Status
A
B
Page 77
command
[Page
37] summarizes alarm codes in
MDS 05-3438A01, Rev. F
screen,
screen,
NO ALARMS