Scd [0-255]; Ser; Show [Dc/Pwr/Current/Radio] - GE MDS 4790 Series Installation & Operation Manual

400 mhz/900 mhz multiple address system master station radio
Table of Contents

Advertisement

Soft-Carrier Dekey
Serial Number
Show Selected
Parameters
54
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx
Entering the
command without a parameter displays the timer
RXTOT
value in minutes. Entering the
ranging from 1 to 1440 resets the timer in minutes. Entering the
command with the parameter
is
.
NONE

SCD [0-255]

The "soft-carrier dekey" command sets or displays the amount of time
to wait after a de-key request before actually de-keying the radio's trans-
mitter.
Entering the
command without a parameter displays the timer value
SCD
in milliseconds. Entering the
from 0 to 255 resets the timer in milliseconds. The default setting is 0,
which means that the radio de-keys immediately following removal of a
keying signal
(see "Simplex and Switched Carrier Operation" on
Page
4).
If you experience problems with repeater operation after changing the
,
or
values, contact GE MDS Technical Support.
CTS
PTT,
SCD

SER

This command displays the radio's serial number as recorded at the fac-
tory.

SHOW [DC/PWR/CURRENT/RADIO]

The
command discloses different types of radio information,
SHOW
depending on the command parameter entered. These are:
—Displays DC input/output voltages.
DC
—Displays the actual (measured) RF power output in dBm.
PWR
Unlike the
PWR
measured, not the programmed RF power setting.
—Shows the low noise amplifier and total board cur-
CURRENT
rent.
—Shows the currently active radio (A or B).
RADIO
MDS 4790/9790 Series I/O Guide
command with a parameter
RXTOT
disables the timer. The default value
NONE
Transmit Timeout
A
B
Page 71
command with a parameter ranging
SCD
Serial Number
A
B
command, this command shows the actual level
MDS 05-3438A01, Rev. F
RXTOT
screen,
screen,
Page 78