Siemens SIWAREX FTA Device Manual page 85

Weighing electronics for automatic scale
Table of Contents

Advertisement

Name
Type
S7-Interface
Reserve
BYTE
Source for the weight
BYTE
simulation
Decade used for
BYTE
rounding the decimal
places of the process
values
(Float weight values)
Reserve
BYTE
Force service operation
BYTE
Process value 1 for fast
BYTE
output to the SIMATIC
CPU
Process value 2 for fast
BYTE
output to the SIMATIC
CPU
Reserve 2
BYTE
S7-Alarm
Definition of process
WORD
alarm 0
Definition of process
WORD
alarm 1
Definition of process
WORD
alarm 2
SIWAREX FTA
Address
Default
Range of Values / Explanation
0
DBB000
0
DBB001
0
0: Weight simulation inactive
1: Weight simulation value of SIMATIC
2: Weight simulation value of RS232
Other definitions not permitted.
DBB002
3
0: Round to 0 decimal places
1: Round to 1 decimal place
2: Round to 2 decimal places
3: Round to 3 decimal places
4: Round to 4 decimal places
5: Round to 5 decimal places
6: Round to 6 decimal places
DBB003
0
Reserve
DBB004
0
Bit 0 :
0: Outputs in service operation - Forced
operation not possible
1: Outputs in service operation - Forced
operation possible
Bit 1 - 7 not used
DBB005
1
Various process values are available for
selection after listing.
DBB006
2
Various process values are available for
selection after listing.
DBB007
0
Reserve 2
DBB008
0
Value 0 - No process alarm generation
Value range 1 – 0FFh
Number of the technical error
Value range 100h – 13Fh
100h+ 0...1Fh Bit-No. NAWI-status bit - coming
100h+ 20h...3Fh Bit-No. AWI Status flag - coming
Value range 200h – 23Fh
200h+ 0...1Fh Bit-No. NAWI status bit - going
200h+ 20h...3Fh Bit-No. AWI status bit - going
DBB010
0
Value 0 - No process alarm generation
Value range 1 – 0FFh
Number of the technical error
Value range 100h – 13Fh
100h+ 0...1Fh Bit-No. NAWI-status bit - coming
100h+ 20h...3Fh Bit-No. AWI Status bit - coming
Value range 200h – 23Fh
200h+ 0...1Fh Bit-No. NAWI status bit - going
200h+ 20h...3Fh Bit-No. AWI status bit - going
DBB012
0
Value 0 - No process alarm generation
Value range 1 – 0FFh
Number of the technical error
Value range 100h – 13Fh
100h+ 0...1Fh Bit-No. NAWI-status bit - coming
Weighing Functions
Reference
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
5.6.6
5.6.6
5.6.6
5-73