Error
Data and
No.
command errors -
description
132
133
134
135
136-
Plausibility error
165
Weighing
parameter
136
Start not possible
because the set
value is not
permitted
137
138
Start not possible
since the fine shut-
off point is not
plausible.
139
140
141
Start not possible
because of possible
overfilling
142
Start blocked
143
Start not possible
since the loading
quantity or the
residual quantity is
too small
144
145
Start not possible
since the set value
< min. WB1
146
Reserved
147
Start not possible
since tolerance limit
(n) is implausible
148
Check stop not
possible
SIWAREX FTA
Solution
Reserved
Reserved
Reserved
Reserved
The set value in DR 20 is invalid. It may not be 0 nor may it be
greater than the maximum permitted set value for a single fill in
DR 23. Correct the parameter.
Reserved
Start not possible since the default for the trailing weight or the
shut-off correction value is not plausible. The following must
apply: (Current trailing - shut-off correction value) <= Set value.
Check the default in DR 22.
Reserved
Reserved
Start not possible since the defined set value does not match the
current scale status.
The following must apply:
Current gross + set value (DR20) – current trailing + shut-off
correction value < maximum weighing range
Start not possible since a blockage is set in weighing step 0.
The defined loading quantity is too low or start is not possible
because the residual quantity that is still to be loaded is too little.
The quantity to be loaded in DR 21 is less than the defined
minimum weight definition in DR 3. Correct the value.
The quantity to be loaded in DR 21 is lower than the current
trailing weight in DR 22. Correct the value.
The quantity to be loaded in DR 21 is lower than the minimum
weighing range value in DR 3. Correct the values.
A dosage in AWI totalizing loading operation cannot be started
since the residual quantity is less than the defined minimum
weight. E.G. If everything has been loaded already or the
loading procedure has been aborted. Give command "Delete
calibratable distribution memory" (113) to activate a new loading
procedure.
Reserved
Start not possible since the set value is less than the minimum
weight of weighing range 1 DR 3. Increase the set value.
Reserved
The tolerance definitions are not plausible.
During the start or while transferring the DR 20 or 22 in the cycle,
a set value was set which is less than at least one of the
tolerance limits TU2, TU1, TO1, TO2. Check tolerance definitions
or the set value.
Check stop not possible since no check stop has been defined.
Messages and Diagnostics
7-147