Hitachi IJ UX Service Manual page 214

Hide thumbs Also See for IJ UX:
Table of Contents

Advertisement

Coat the high-voltage electrical power lines setscrew part with silicon rubber according to
the following procedure.
①Fill the top and bottom of the ring terminal with silicon rubber, using a dispenser.
Caution
a) Hold the head as shown below in order to prevent the silicone from
High-voltage line terminal
running.
(round terminal)
Dispenser
Insert the tip of the dispenser
into the downside of the
terminal to fill the downside
space.
10~20mm
b) Fill it up with the silicone sufficiently as shown below.
Fill it up to approximately the same
height as the rib of the base plate so that
the screw head will not be out.
Fill up the downside of the terminal as well.
Silicone Filling Portion
(Hatching Portion)
D section
High-voltage line terminal
(round terminal)
Dispenser
If
almost filled, fill up the
upside of the screw.
Nozzle
The metallic portion of the
high-voltage line terminal portion
should be completely hidden.
Rib of the base plate
Rib
High-voltage round terminal
5-20
the
downside
is

Hide quick links: