4.8.2
Drive unit replacement procedure
1 Perform "Ink drainage" to "Pressure relief".
2 Turn off the power supply.
3 Perform "4.1.3 Access to the parts on the rear side of the equipment", "(1) Access
method from the front" and open the unit door.
[Caution] Be careful not to catch the tubes.
4 Remove the wires from clamps (5 positions).
5 Remove the Motor connection connector.
Clamps
Drive unit
4-21
Clamp
Motor connection
connector