Bosch DCN Next Generation Installation & User's Instructions page 165

Digital congress network
Hide thumbs Also See for DCN Next Generation:
Table of Contents

Advertisement

DCN Next Generation | Installation and User Instructions | Flush-mounted Devices
19.3.2 Block-mounting
Refer to figure 19.2 for the dimensions of a recess for
the block-mounting method.
figure 19.3: Recess, block-mounting method
The length (x) of a recess depends on the total
number-size factor (NSF) of the flush-mounted devices
that must be installed in the recess. To calculate the
length of a recess:
1 For each flush-mounted device, get the number-size
factor (NSF) from table 19.3.
2 Add the NSFs of the flush-mounted devices to get
the total NSF.
3 Use the total NSF to get the length (x) of the recess
from table 19.2. The length includes the
DCN-FCOUP couple pieces.
Note
Install DCN-FEC End Caps on the couple
pieces at the two ends of the recess.
table 19.2: Lengths, block-mounting method
Total NSF
1
2
3
4
5
6
7
8
9
10
11
12
Bosch Security Systems | 2007-02 | 9922 141 70525
x (mm)
71.5
121.5
171.5
221.5
271.5
321.5
371.5
421.5
471.5
521.5
571.5
621.5
19.3.3 Number-size factor
The length of a recess depends on:
The number of flush-mounted devices that are
installed in the recess.
The size of the flush-mounted devices that are
installed in the recess.
To calculate the length of a recess, you must use the
number-size factor (NSF, refer to table 19.3) of the
flush-mounted devices.
table 19.3: Number-size factors
Flush-mounted device
DCN-FCS
DCN-FLSP
DCN-FMIC
DCN-FMICB
DCN-FPRIOB
DCN-FV
DCN-FVCRD
DCN-FVU
DCN-FVU-CN
en | 165
NSF
2
2
1
1
1
2
2
2
2