The PGM input is a special input that can be configured
to accept data from a number of different RF receiver
manufacturers or simply be used as an keyswitch input.
The tamper options configure the system behaviour for
cabinet tamper alarms and also for the cabinet tamper of
the peripheral devices.
I N P U T CO M M A N D S
Inputs > Commands >

Zone Status

This menu allows you to view the zone status of each zone
(i.e. Normal, Alarm or Tamper etc).
1) Enter [MENU] + [3] + [0] + [0] and select the zone
you want to view from the list then press [OK].
Alternatively, you can directly enter the zone
number to view then press [OK].
2) The keypad will display the zone status and EOL
resistance value.
Zone 1 Name Zn1
EOL=Normal 06523 Ohms
Press OK or MENU
3) Press the [OK] key to exit.
Inputs > Commands >

Zone Array

This menu allows you to view zones in groups of sixteen.
The top two rows of the display show the zone number,
the third row displays the zone status
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
If a 100 is displayed at the right hand side of the top line,
it means that you are displaying zones 97 to 112 or zones
113 to 128 etc. See example.
1) Enter [MENU] + [3] + [0] + [1] and use the up and
down arrows to select the zone group to view.
2) Use the up and down arrows at any time to move to
a new group. The keypad will display the following
zone array information for zones 1 to 16.
0000000001111111
1234567890123456
NSA-ANAT--------
Press  OK or MENU
In the above example screen,
N = Zone 01 and 06 are Normal (Sealed)
7-2
Input Programming
-
-
-
MENU 3-0-0
-
MENU 3-0-1
S = Zone 02 is Shorted
A = Zone 03,05,07 are in Alarm (Unsealed)
T = Zone 08 is in Tamper Alarm (Unsealed)
- = Zone 04, 09-16 are Disabled (Unused)
3) The keypad will display the following zone array
information for Zones 97 to 112.
9990000000000111 1
7890123456789012 0
---------------- 0
Press  OK or MENU
4) The keypad will display the following zone array
information for Zones 113 to 128.
1111111222222222 1
3456789012345678 0
---------------- 0
Press  OK or MENU
5) When finished press [OK] or [MENU] to exit.
Inputs > Commands >

Bypass Zones

This menu allows users with the appropriate access level
to manually bypass zones effectively removing them
from the area for the current arming cycle. All zone types
including 24hour zones can be bypassed. Bypassed zones
will be reset when the area is turned off or disarmed.
1) Enter [MENU] + [3] + [0] + [2]. A list of zones that
can be bypassed will display on the keypad. A tick
displayed on the right side of the zone name
indicates that the zone is already bypassed.
Zn1 Zone 1 Name 
Zn2 Zone 2 Name
Zn3 Zone 3 Name
Press  OK or MENU
2) Using the up and down arrow keys highlight the
zone that you want to bypass, then press [OK].
Alternatively, you can enter the zone number that
you want to bypass, then press [OK]. If the zone is
bypassed, the keypad will prompt:
Zone 1 Name Zn1 is
bypassed. To un-bypass,
press OFF.
Press OK or MENU
3) If the zone is not bypassed, the keypad will prompt:
-
-
MENU 3-0-2
Bosch Security Systems 07/14 BLCC610I