F E AT U R E S
Listed below are the main features of the Solution 6000
Control Panel.
Individual Box Tamper Circuit Monitoring
Report Via Email (Internet)
Telephone Line Busy Tone Detect
RAS Intelli-Connect® CLI Caller Line Identification
Daylight Savings
Senior Watch
System Maintenance Interval Reminder
System Weekly Test Reminder
Area Inactivity Interval
Temporary PIN
Dual Reporting
Dual Redundant Reporting
Alarm Report Abort/Cancel Options
8 Programmable Holiday Calendars
16 Programmable Door Assignments
8 On-board Zones (Exp To 144 Zones)
Fire Alarm Verification
255 PIN Users
4 Supervised High Power Digital Outputs
1 Relay 2 Amp Form (C) Contact (Expandable to 32)
Supervised Siren Driver
Partitionable To 8 Areas
Dialler Reports SIA, Contact ID, SMS and Email Formats
Supervised LAN Keypads (Maximum 16 Keypads)
Keyswitch Input
1000 History Event Memory
EMI / Lightning Transient Protection
Fully Menu Text Programmable
Programmable Via Solution Link Software (Remote/Direct)
Telephone Line Fail Monitor
Time Executed Functions
60+ Output Event Types
Exit Restart
Expansion Module Supervision
DTMF Tone Decoder Built In
Remote Arming
Bosch Security Systems 07/14 BLCC610I
O V E R V I E W
Zones
The Solution 6000 control panel provides up to 144
separate zones of protection.
determines the panel's response to open/short and
tamper conditions on the zone loop.
Areas
The control panel supports up to 8 separate areas. You
can assign all zones to a single area, or you can assign
each zone to a combination of different areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports
to the receiving party (ie. Security company monitoring
station, mobile phone etc).
Keypads
You can connect a maximum of 16 fully supervised
keypads to the control panel. The available current affects
the total number of keypads that you can connect without
the need to provide additional power supplies.
History Log
The control panel can store up to 1000 history events from
all 8 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel's history log via keypad,
serial printer (optional), or by connection of a personal
computer (direct/remote) using the Solution Link upload/
download software.
Programming
You can program the control panel either by a keypad
or using a personal computer using the Solution Link
upload/download software.
S E C TIO N 1

Overview

Zone programming
1-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents