DT M F CO N T R O L F U N C T I O N S
Firmware includes comprehensive DTMF control of
individual areas and outputs with full user PIN and TIMER
GROUP access verification.
Unlike other systems, no additional hardware or modules
are required for DTMF control. To configure the desired
functions see MENU 5-3-5 DTMF Options.
How to Use DTMF Control
1) Once the panel answers the incoming call, if either
option 1, 2, 3 or 4 in MENU 5-3-5 is enabled, then
the panel will play a short welcome jingle. You now
have approximately 5 seconds to enter a valid PIN
and log onto the panel.
2) Enter PIN followed by the [#] key. If the PIN is valid
the system will respond with two short beeps. If the
PIN is invalid then a single long beep will be heard.
If a valid PIN is not entered in time, the panel will attempt
to establish a modem connection as if connecting to the
Solution Link software.
If this happens you will need to hang up for approximately
60 seconds before trying again.
3) Once validated, the following commands can be
performed. See the table below. If no keys are
pressed for 20 seconds then the panel will play the
exit jingle before terminating the session and
hanging up. Pressing [#][#] at any time while
connected will cause the panel to terminate the
session.
DTM F CO NTRO L F UNC T IONS
Operation
Quick Arm
All Areas
Log In
OK
Error
Incorrect Entry
Turn Area
[1] + [Area N
ON
Turn Area
[1] + [Area N
OFF
Turn Output
[2] + [Output N
ON
Turn Output
[2] + [Output N
OFF
End
Session
Table 17: DTMF Remote Control Functions
4-6
Programming Overview
Tone
Command
Response
High,
[0] + [#]
Medium,
[PIN] + [#]
Low, High
Long Beep
] + [#] + [1]
Low, High
o
] + [#] + [2] + [#]
High, Low
o
o
] + [#] + [1] + [#]
Low, High
o
] + [#] + [2] + [#]
High, Low
High,
[#] + [#]
Medium,
DT MF EXA MP LES
Each example below shows the log on step for clarity. In
practise is only necessary to log on once per DTMF control
session.
To turn Area 1 ON enter the following
[1] + [1] + [#] + [1]
To turn Output 10 ON enter the following
[2] + [1] [0] + [#] + [1]
To turn Output 12 OFF enter the following
[2] + [1] [2] + [#] + [2]
If the DTMF Quick Arm option is enabled
i
then
Note
areas
Simply enter [0] + [#] following the welcome jingle.
Make sure that the phone being used to remotely
control the panel is set to transmit DTMF tones
when keys are pressed during the call. This option is
disabled by default on some phones.
Low
Low
[2] [5] [8] [0] [#]
= Log ON
= Arm Area 1
= Log ON
[2] [5] [8] [0] [#]
= Turn Output 10 ON
[2] [5] [8] [0] [#]
= Log ON
= Turn Output 12 OFF
it
is
possible
to
remotely
without
logging
onto
Bosch Security Systems 07/14 BLCC610I
arm
all
the
panel.