Automatic Rebuilding With A Hot Spare; Rebuilding The Disk Array Using Power Console Plus - Toshiba Magnia 3200 User Manual

Hide thumbs Also See for Magnia 3200:
Table of Contents

Advertisement

System Configuration Setup
The following events may occur if the system load increases significantly:
Event ID: 9
Source:mraid35x
(Explanation) Device SCSI Port did not reply within the time-out.
- Displayed at the "Application Log" of the NT Event Viewer
No MegaRAID Adapter card found!
[OK]
If the above messages appear, reduce the load by pressing the Enter key, and then
restarting Power Console.

Automatic rebuilding with a hot spare

If the server is configured with a hot spare (standby disk), you can rebuild the disk array
using the hot spare, even if a hard disk drive (other than the hot spare) is malfunctioning.
When the rebuild completes, the status indicators on that hard disk drive will turn off. To
ensure that the fault alarm operates properly, set Alarm Control to "Enabled."

Rebuilding the disk array using Power Console Plus

When rebuilding the server's disk array, the following error may occur when you start
Power Console:
!!!Error on starting device!!!
[OK]
If this error message appears on screen, press the Enter key before restarting the
rebuilding process.
Disk array (RAID) settings
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnia 3200r

Table of Contents