Relay Control Function Key - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

RELAY CONTROL FUNCTION KEY

PROGRAMMING
START
CM10
Assign the DK card to the required LEN.
NOTE 1:
NOTE 2:
CM14
Assign the DK card to the required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
NOTE 2:
CM08
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
CM44
Assign the function of relay control via D
to the DK.
CM90
Assign the Relay Control (ON/OFF) key on
the required D
END
DESCRIPTION
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
Circuit No. 3 of E831 is used for
built-in External Equipment Inter-
face of MP card by setting CM44.
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
Circuit No. 3 of E831 is used for
built-in External Equipment Inter-
face of MP card by setting CM44.
term
.
PROPRIETARY MULTILINE TERMINAL
(1)
000-763: LEN
(2)
E800-E831 : DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
E800-E831 : DK Card No.
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
(1)
700
(2)
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
term
(1)
XX Y
XX : 00-31: DK Card No. E800-E831
assigned by CM10/CM14
Y : 0-3: Circuit No.
313: MP Built-in External Equipment In-
terface
(2)
1500: Relay Control (On/Off) Function
Key via D
Y=00
(1)
My Line No. +
(2)
F7 XX Z
XX: 00-31: DK Card No. assigned by
CM44
Z : 0-3: Circuit No. assigned by CM44
– 584 –
RELAY CONTROL FUNCTION KEY
DATA
term
,
+ Key No.
NWA-008845-001 Rev.5.0