DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK
PROGRAMMING
START
CM02
Assign the system clock data.
CM65
Select the two kinds of mode change or the
four kinds of mode change per each tenant.
Assign whether the Trunk Restriction Class is
changed according to the schedule of Day/
Night Mode Change by System Clock.
NOTE:
A
DESCRIPTION
In four kinds of mode change, the trunk restriction class is changed as follows:
• Day Mode
Day Mode
• Night Mode/Mode A/Mode B
DAY/NIGHT MODE CHANGE BY SYSTEM CLOCK
(1)
0: Calendar Year
(2)
2000-2099
(1)
1: Date
(2)
MM DD WW
MM : 01-12 (Month)
DD : 01-31 (Date)
WW: 00 (Sun)
01 (Mon)
02 (Tue)
03 (Wed)
04 (Thu)
05 (Fri)
06 (Sat)
(1)
2: Time
(2)
HH MM SS
HH : 00-23 (Hour)
MM: 00-59 (Minute)
SS : 00-59 (Second)
•
Y=29
(1)
00-63: Tenant No.
(2)
0 : Two kinds of mode
(Day Mode, Night Mode)
1 : Four kinds of mode
(Day Mode, Night Mode, Mode A,
Mode B)
•
Y=36
(1)
00-63: Tenant No.
(2)
0 : Provide
(Day Mode/Night Mode only)
1 : Not provided
Night Mode
– 531 –
NIGHT SERVICE
DATA
NWA-008845-001 Rev.5.0
32ch1009.fm