RECALL KEY

PROGRAMMING
For internal call:
RECALL Key is initially assigned to all D
For outside call:
START
CM35
Assign the data for hookflash signal sending to
the route number assigned by CM30 Y=00.
CM90
Assign a Flash Over Trunk key to the required
term
D
.
CM41
Specify duration of the hookflash signal to
trunks.
END
HARDWARE REQUIRED
term
D
and DLC card
term
s.
DESCRIPTION
PROPRIETARY MULTILINE TERMINAL
Y=16
(1)
00-63: Trunk Route No.
(2)
1 : Sending
Y=00
(1)
My Line No. +
(2)
F1009
Y=2
(1)
17
(2)
02-30: 128-1920 ms.
If no data is set, default setting is 576-640 ms.
– 583 –
RECALL KEY
DATA
,
+ Key No.
(64 ms. increments)
NWA-008845-001 Rev.5.0