QUEUE LIMIT FOR TAS
PROGRAMMING
In addition to the TAS programming (
START
CM64
Assign the number of Queue Limit for TAS to
each mode and tenant.
CM76
Specify the terminating system as TAS.
Specify whether the incoming call of each DID
number is restricted by Queue Limit for TAS.
NOTE:
A
Page
DESCRIPTION
When there are two or more DID
numbers for one tenant, and if you
want to set the Queue Limit only for
one DID number, set "0" to the DID
number, and set "3" for the other
DID numbers.
If you want to set the Queue Limit
for one DID number and the other
DID numbers concurrently, set "0"
to the DID number, and set "2" to
the other DID numbers.
543), do the following programming.
•
Y=3 Day Mode
•
Y=4 Night Mode
•
Y=5 Mode A
•
Y=6 Mode B
(1)
00-63: Tenant No.
(2)
01-99
NONE : No limit
•
Y=01 Day Mode
•
Y=02 Night Mode
•
Y=03 Mode A
•
Y=04 Mode B
(1)
000-999: Number Conversion Block No.
(2)
D13: TAS
•
Y=16
(1)
000-999: Number Conversion Block No.
(2)
0 : Restricted
2 : Not restricted
(countable for Queue Limit)
3 : Not restricted
(uncountable for Queue Limit)
– 540 –
NIGHT SERVICE
QUEUE LIMIT FOR TAS
DATA
: 1-99 lines
assigned by CM76 Y=00/90
assigned by CM76 Y=00/90
NWA-008845-001 Rev.5.0